Legislation

Search OpenLegislation Statutes

This entry was published on 2014-09-22
The selection dates indicate all change milestones for the entire volume, not just the location being viewed. Specifying a milestone date will retrieve the most recent version of the location before that date.
SECTION 53
Fire-escapes
Multiple Dwelling (MDW) CHAPTER 61-A, ARTICLE 3, TITLE 2
§ 53. Fire-escapes. Every fire-escape erected after April eighteenth,
nineteen hundred twenty-nine, shall be located, arranged, constructed
and maintained in accordance with the following provisions:

1. Access to a fire-escape shall be from a living room or private hall
in each apartment or suite of rooms at each story above the entrance
story, and such access shall not include any window of a stairhall.

a. Such room or private hall shall be an integral part of such
apartment or suite of rooms and accessible to every room thereof without
passing through a public hall.

b. When one or more living rooms of any apartment are rented to
boarders or lodgers, every such room shall be directly accessible to a
fire-escape without passing through a public hall, and for separately
occupied living rooms access to fire-escapes shall be direct from such
rooms without passing through a public hall or any other separately
occupied room, except as may be permitted for dormitories in section
sixty-six.

c. Access to any fire-escape shall not be obstructed by sinks or
kitchen fixtures or in any other way. Iron bars, grilles, gates, or
other obstructing devices on any window giving access to fire-escapes or
to a required secondary means of egress shall be unlawful unless such
devices are of a type approved by the board of appeals and are installed
and maintained as prescribed by the board; provided, however, that in a
city having a population of one million or more, such devices shall be
of a type approved, installed and maintained as prescribed by the fire
commissioner, or as previously approved and prescribed by the board of
standards and appeals of such city, except as otherwise provided by said
commissioner.

d. Every such fire-escape shall be accessible to one or more exterior
doors or windows opening from the room, apartment, suite of rooms or
other space which it serves as means of egress, and such window or door
shall be two feet or more in clear width and two feet six inches or more
in clear height. The sill of any such window shall be within three feet
of the floor.

2. A required fire-escape may be erected in any of the following
places:

a. On a wall facing a street or yard;

b. In a court of a non-fireproof multiple dwelling to serve an
apartment or suite of rooms which does not contain any room fronting
upon a street or yard, or in any inner court thirty-five feet or more in
its least horizontal dimension, provided the fire-escape does not
project more than four feet from the wall of the dwelling and is
directly connected at the bottom of such court with a fireproof
passageway at least three feet wide and seven feet high leading directly
to a street unless the court itself leads to a street;

c. In any outer court eighteen feet or more in width and thirty feet
or less in length;

d. In any outer court more than eighteen feet in width the length of
which does not exceed its width by more than seventy per centum;

e. In any outer court ten feet or more in width at every point and
situated on a lot line;

f. In any outer court seven feet or more in width at every point which
is situated on a lot line and extends from a street to a yard;

g. In a recess on the front wall of a multiple dwelling, provided the
recess does not exceed five feet in depth, is used solely for
fire-escape purposes and has seventy-five per centum or more of its area
open to the street, and is otherwise unenclosed and open at the top. No
such recess shall be counted as a part of the unoccupied area of the
premises or be construed as a court unless its entire area is open to
the street.

3. No fire-escape may project more than four and one-half feet into a
public highway from the lot line of the multiple dwelling it serves.
Every part of such fire-escape shall be at least ten feet above any
sidewalk directly below.

4. a. Every fire-escape shall be constructed of open balconies and
stairways of iron or stone capable of sustaining a load of at least
eighty pounds per square foot. The use or reuse of old materials or cast
iron in the construction of fire-escapes shall be unlawful.

b. Balconies for fire-escapes shall be three feet or more in clear
width except that a party-wall balcony as permitted by paragraph f of
subdivision one of section one hundred eighty-seven may be two feet in
clear width.

c. Every stairway shall be placed at an angle of sixty degrees or less
with flat open steps at least six inches in width and twenty inches in
length and with a maximum rise of nine inches. The opening in any
balcony for such a stairway shall be at least twenty-one by twenty-eight
inches.

5. a. There shall be provided from the lowest balcony a drop ladder
fifteen inches in width and of sufficient length to reach to a safe
landing place beneath. Such ladder shall be constructed, located and
arranged so as to be held in proper position at all times and, unless
properly counter-balanced, shall be placed in guides so that it can be
easily lowered.

b. The distance from the lowest balcony to the ground or safe landing
place beneath shall be not more than sixteen feet, except that the
department may permit such lowest balcony to be up to eighteen feet
above a public sidewalk because of structural conditions in any multiple
dwelling erected before April eighteenth, nineteen hundred twenty-nine.

c. No drop ladder shall be required where the distance from the lowest
balcony to a safe landing place beneath is five feet or less.

6. The balcony on the top story shall be provided with a stairway or a
gooseneck ladder from such balcony to and above the roof and securely
fastened thereto, except that no such stairway or ladder shall be
required:

a. On multiple dwellings two stories or less in height erected after
April eighteenth, nineteen hundred twenty-nine; or

b. Wherever there is a peak roof with a pitch in excess of twenty
degrees;

c. When the fire-escape is on the front of the dwelling, in a recess
on the front of the dwelling, or on an outer court opening to a street.

7. Every fire-escape if constructed of material subject to rusting
shall be painted with two or more coats of good paint in contrasting
colors; in the case of a new fire-escape the first coat before erection,
and the second coat after erection. Whenever a fire-escape becomes
rusty, the owner shall repaint it with two additional coats of good
paint.

8. a. Whenever a non-fireproof multiple dwelling is not provided with
sufficient means of egress in case of fire, the department may order
such additional fire-escapes or balconies as in its judgment may be
deemed necessary.

b. The owner of a multiple dwelling shall keep and maintain every
fire-escape thereon in good order and repair.

c. No person shall at any time place any encumbrance of any kind
before or upon any fire-escape, or place or keep a cover of any kind
over the stairway opening in a balcony of such fire-escape. An occupant
or tenant of a multiple dwelling who shall violate or assist in the
violation of the provisions of this paragraph shall be guilty of a
misdemeanor punishable as provided in section three hundred four.

9. No fire-escape shall be removed from or constructed on any existing
multiple dwelling without permission from the department. No fire-escape
shall be removed from any apartment without due precaution against
leaving occupants of such apartment without adequate means of egress in
case of fire. A wire, chain cable, vertical ladder or rope fire-escape
is an unlawful means of egress. Every such fire-escape, if required as a
means of egress, shall be removed and replaced by a system of
fire-escapes constructed and arranged as provided in this section.

10. The department shall have the power to make supplementary
regulations relating to fire-escapes.